99久久婷婷国产麻豆精品电影_国产av无码一区二区二三区j_色成人网站WWW永久在线观看_免费人成激情视频在线观看冫

產品列表PRODUCTS LIST

首頁>產品中心>>蓄電池負載測試儀>YHFD-48V100A蓄電池恒流放電負(fu)載測(ce)試儀(yi)
YHFD-48V100A蓄電池恒流放電負載測試儀

發布時間:2023-11-10

簡要描述:

YHFD-48V100A蓄電池恒流(liu)放(fang)電負(fu)載測試儀采用(yong)了大功(gong)率放(fang)電模塊和新型的發熱元件(jian),具有重量輕,攜帶方便和質量可靠等特點(dian)。

在線留言
YHFD-48V100A蓄電池恒流放電負載測試儀

YHFD-48V100A蓄電池恒流放電負載測試儀

產品簡介

YHFD蓄電池恒流放電負載測試儀采用了大功率放電模塊和新型的發熱元件,具有重量輕,攜帶方便和質量可靠等特點。它具有以下功能:限壓、*、限容量、自動報警及現場存儲功能,無須人為干擾,進一步提高工作效率。蓄電池恒流放電負載測試儀廣泛適用于電力局、電廠、變電站、通訊公司及 UPS 不間斷電源等場合。

YHFD-48V100A蓄電池恒流放電負載測試儀

產品特點

1、蓄(xu)電(dian)(dian)池恒流(liu)放電(dian)(dian)負載測試儀LCD背光顯(xian)示

2、可設(she)定恒電流放電值(無段(duan)式):1~100A連(lian)續可調。

3、可設(she)定(ding)蓄(xu)電池組放電終止電壓:連續可調(diao),數字面板輸入。 

4、蓄電(dian)池恒流放(fang)電(dian)負載測試儀可設(she)定累(lei)計放(fang)電(dian)容量(AH值)

5、所有高(gao)效能電熱元件均符合(he)UL安(an)全規格 

6、*采(cai)用(yong)高效(xiao)能電(dian)熱(re)元件,無任何電(dian)熱(re)絲,即(ji)使(shi)風扇故(gu)障(zhang)也不(bu)會(hui)產生紅熱(re)危險

7、蓄電(dian)(dian)(dian)池恒(heng)流放電(dian)(dian)(dian)負載測試儀可多部并聯放電(dian)(dian)(dian),以適應大(da)電(dian)(dian)(dian)流放電(dian)(dian)(dian)的場合(he) 

8、可與蓄(xu)電池組在線(xian)容量監測設(she)備(BCSU)連線(xian)作業,有(you)報警(jing)自動停止放電

9、蓄(xu)電池恒流放(fang)電負載測試儀中(zhong)文視窗界面(mian)顯示,操作簡單

10、與(yu)PC機連(lian)線,采用(yong)WINDOWS的作業環境,易于(yu)操作,且(qie)可同時顯示蓄電(dian)池組恒流放電(dian)容量(liang)測(ce)試設備(BDCT)與(yu)蓄電(dian)池組在線容量(liang)監測(ce)設備(BCSU)的曲線圖

11、采用特殊大電流夾頭,不必(bi)拆開電池(chi)的(de)接頭,即(ji)可直接夾住測(ce)試,簡單又方便

12、蓄(xu)電(dian)池恒流放電(dian)負載測試(shi)儀帶(dai)有RS232數據轉存接口(kou)。 

13、主機內(nei)置存儲(chu)器,可(ke)存儲(chu)紀(ji)錄(lu),無須攜帶電腦,單機即可(ke)工(gong)作;日后(hou)用電腦打(da)印報(bao)告即可(ke)。

14、帶有電壓電流校準(zhun)修正功能,可隨時對儀表的測量值進行(xing)校準(zhun)修正,保(bao)證(zheng)測量精度。

15、蓄電(dian)池恒流(liu)放電(dian)負(fu)載測試儀帶(dai)有正負(fu)電(dian)纜(lan)線防反(fan)接功能(neng),避免正負(fu)級接反(fan)引起短(duan)路(lu)。

16、帶有掉電(dian)保存(cun)功能。掉電(dian)后所有測試(shi)數據不丟失(shi),加電(dian)后繼續工作,防止意外掉電(dian)影響取得(de)完整的測試(shi)結果

17、蓄(xu)電池恒流放電負載測試儀帶有數據分析打印軟件,分析打印放電曲線,放電容(rong)量,自(zi)動生成測試報(bao)告(gao)。

功能

◆ 核對性(xing)放(fang)電試驗 

   可(ke)連續設定放(fang)電(dian)(dian)電(dian)(dian)流(liu)。按(an)設定的放(fang)電(dian)(dian)電(dian)(dian)流(liu)恒流(liu)放(fang)電(dian)(dian),監(jian)測(ce)放(fang)電(dian)(dian)過(guo)程(cheng)中電(dian)(dian)池(chi)組及單節電(dian)(dian)壓,測(ce)量(liang)單節電(dian)(dian)池(chi)組的容量(liang)(核對性(xing)容量(liang)實驗)。

   多種放電停(ting)止條件設定:

   A、電(dian)(dian)池組(zu)總電(dian)(dian)壓    B、單體(ti)電(dian)(dian)池電(dian)(dian)壓

   C、放電(dian)時間(jian)        D、放電(dian)容(rong)量

   多種(zhong)單體(ti)電池適應:2V、4V、6V、12V

   無(wu)線單體電(dian)池(chi)電(dian)壓(ya)采集,1個采集盒可接12節2V、4V電(dian)池(chi),4節6V、12V電(dian)池(chi)      

◆ 快速測量

   短時(10~20分鐘(zhong))放電(dian),快速測試單體電(dian)池(chi)內(nei)阻及放電(dian)能(neng)力(li),快速判別(bie)電(dian)池(chi)性能(neng)。

◆ 停電(dian)(dian)后在線實際(ji)負載放(fang)電(dian)(dian)測(ce)試電(dian)(dian)池組容量

   停電(dian)時/實際負載放(fang)電(dian)時,在(zai)線自動(dong)監測(ce)單體電(dian)池(chi)(chi)電(dian)壓、電(dian)池(chi)(chi)組電(dian)壓及放(fang)電(dian)電(dian)流,記錄(lu)電(dian)池(chi)(chi) 的放(fang)電(dian)容量,保證對電(dian)池(chi)(chi)狀態的判斷。

◆ 電流監測功能(選配)

   停(ting)電(dian)(dian)(dian)(dian)時/實(shi)際負載放(fang)電(dian)(dian)(dian)(dian)時,在線自動監測單體電(dian)(dian)(dian)(dian)池(chi)(chi)電(dian)(dian)(dian)(dian)壓(ya),電(dian)(dian)(dian)(dian)池(chi)(chi)組電(dian)(dian)(dian)(dian)壓(ya)及放(fang)電(dian)(dian)(dian)(dian)電(dian)(dian)(dian)(dian)流,記(ji)錄電(dian)(dian)(dian)(dian)池(chi)(chi)的放(fang)電(dian)(dian)(dian)(dian)容量,保(bao)證(zheng)對電(dian)(dian)(dian)(dian)池(chi)(chi)狀態的判斷。

◆ 充電(dian)電(dian)壓監測功能

   在(zai)核對(dui)性放(fang)電之(zhi)后無(wu)需(xu)拆卸設備及可對(dui)之(zhi)后蓄電池組的充電過(guo)程進行(xing)全程監測,包括(kuo):整(zheng)組充電電壓  單體充電電壓  充電時間

◆ 落后電(dian)池識別功(gong)能(接續放電(dian)功(gong)能)

   在放(fang)(fang)電(dian)過(guo)程(cheng)中當某一節電(dian)池(chi)(chi)達到放(fang)(fang)電(dian)下(xia)限閥(fa)值而整(zheng)(zheng)組電(dian)壓還處(chu)于正常電(dian)壓時可(ke)選擇暫停(ting)放(fang)(fang)電(dian),將落后(hou)提出(chu)后(hou)繼續放(fang)(fang)電(dian),以免將此(ci)電(dian)池(chi)(chi)過(guo)放(fang)(fang),對日后(hou)針對該節電(dian)池(chi)(chi)進行活(huo)化提供科學(xue)的條件。該功能可(ke)以挑出(chu)前6節達到下(xia)限閥(fa)值的電(dian)池(chi)(chi),因為(wei)一旦(dan)超過(guo)6節即認為(wei)整(zheng)(zheng)組電(dian)池(chi)(chi)不達標(biao)。

◆ 接(jie)續放電功能

   還可以(yi)將(jiang)放電工作分(fen)不同工作日(ri)進行,以(yi)方便工作人員的(de)時間安排(pai)。 

◆ PC機無線監測功(gong)能(neng)

   在100m內實(shi)現PC機(ji)對(dui)放(fang)電監測(ce)(ce)系統的無線數據監測(ce)(ce)、告警功(gong)能。

◆ 數據(ju)管理

   完善的計算機管理分(fen)析監控軟(ruan)件,具(ju)有強大的數(shu)(shu)據處理功(gong)能,采用先進的數(shu)(shu)學(xue)模型, 對(dui)電(dian)(dian)池(chi)(chi)的多(duo)項(xiang)(xiang)測量結果進行(xing)(xing)綜合計算分(fen)析,準確判斷電(dian)(dian)池(chi)(chi)性(xing)能,并(bing)可查詢電(dian)(dian)池(chi)(chi)的實(shi)時運(yun)行(xing)(xing)狀(zhuang)態及歷史數(shu)(shu)據,包(bao)括各項(xiang)(xiang)參(can)數(shu)(shu)、曲線(xian),并(bing)生(sheng)成(cheng)報表。

技術參數: